| Fuel |
Waste Heat |
| Place of Origin |
Guangdong China (Mainland) |
| Model Number |
LFL SERIES |
| Output |
Steam |
| Usage |
Industrial |
| Structure |
Other |
| Pressure |
High Pressure |
| Style |
Vertical |
| Type |
Natural Circulation |
Thesteamgeneratingplantconsistsofoneverticalcompositeboiler, the characterstobeasbelow.No. of set:- one (1) Type: -vertical, cylindrical, smoke tube type with pressure atomizedburnerandfeedwaterregulator (ON/OFF) Evaporation Oil firedsection:-800kg/h Exh. gas section: -800kg/h (atC.S.R. of M/E) Steamstate: -0.7Mpa (working) saturated Feedwater temperature:-60°CTheboiler to be well laggedwithheatinsulating material and covered with agalvanizedplate inaccordancewith Maker`sstandard.Accessdoortobeprovidedforinspection.The boilertobedesignedtoburnheavyfueloilsame asmainengine atnormalservice, andMDO tobeusedforcoldstarting.Theboiler topermitasimultaneousoperationofthe oil-firedsectionandtheexhaustgas sectionwhennecessary.Thenormalnecessarysteamatseatobegeneratedbytheexhaustgassectionofcompositeboilerutilizingtheexhaustgasheatofthemainengine.Theexhaustgassectionmay bedryboiledincase ofemergency.Incoldarea, orwhenshiprunsatlowload ofthemainengineorsimilarcondition, assistingoilfiredsectionofcompositeboilertobetakenintoconsideration.Excesssteamshouldbeledtoaatmosphericcondenserviaadumpvalve.